PRODUCT INDEX · POWERCORE-SERIES

Three product families. One engineering standard. Pre-tested, pre-mapped, and under contract for seven years.

Every PowerCore-Series unit ships from our 180,000 sq ft Pasadena assembly facility fully documented, fully witnessed via encrypted video, and backed by a 7-Year Uptime Guarantee that no competitor in our tier will put in writing. Browse the catalog below or specify directly with our applications engineers.

INCLUDED ON EVERY UNIT SHIPPED SINCE 2019 7-Year Uptime Guarantee · 99.97% availability · financial penalties per hour of deviation

Series
PowerCore
Power Range
250 kW — 25 MW
Configurations
Diesel · Gas · Hybrid (BESS)
Lead Time
14–22 weeks
Issued
Q1 2026 · Rev. 11.2
CATALOG STRUCTURE · SELF-SELECT BY LOAD CLASS

Three product families, one engineering standard. Pick the tier that matches your load profile.

Each family is built on the same control architecture, the same emissions platform, and the same factory acceptance testing protocol. The difference is duty cycle, installed footprint, and how the unit integrates with your site.

TIER 02 · CONTINUOUS POWER

PowerCore-CP

1 MW — 25 MW · Utility-Grade

Primary Duty
Continuous Base-Load · Utility Bridge
Heat Rate
7,250 BTU/kWh (gas) · 7,820 (diesel)
Step Load
40% in < 10 seconds
Synchronizing
Up to 32 units in parallel
Watch-Test
Live encrypted video, every unit ≥ 1 MW
TIER 03 · HYBRID MICROGRID

PowerCore-Hybrid

250 kW — 12 MW · BESS-Integrated

Primary Duty
Off-Grid Microgrid · Diesel Displacement
Diesel Reduction
38% avg. across 1,200+ deployed
Controller
Proprietary · 14 active patents
BESS Chemistry
LFP · NMC available
Shipping Milestone
500th unit shipped Q4 2024
TIER 01 · PRIME POWER DETAIL

Prime Power gensets engineered for remote sites, peak-shaving, and standby duty where every kW must start on the first crank.

The PowerCore-PP family covers the 250 kW to 2.5 MW load band across diesel and natural-gas prime movers. Configurable for 480 V to 13.8 kV service, every unit ships with a factory-mapped control board, on-board paralleling switchgear, and a witnessed live factory acceptance test before crate-out.

Standard Configuration

  • Engine Platforms: Tier 4 Final diesel (CAT 3516, MTU 8V4000, Cummins QSK60) or lean-burn natural gas (Jenbacher J412, MTU 6V4000)
  • Alternator: Marathon, Stamford, or Leroy-Somer — IP23 drip-loop enclosure as standard, IP54 available
  • Controller: WCC-7000 paralleling controller with DNP3 / Modbus / IEC 61850 protocol stack
  • Fuel System: Sub-base UL 142 double-wall tank (8–24 hr runtime) or remote belly tank
  • Emissions Aftertreatment: SCR + DOC + DPF for diesel; oxidation catalyst for gas

Voltage & Fuel Configuration Matrix

  • Diesel480 V / 600 V / 4.16 kV
  • Natural Gas480 V / 600 V / 13.8 kV
  • Dual-Fuel480 V / 600 V
  • Containerized SkidAll voltages · ISO 20/40 ft
QUALIFICATION ARTIFACT · EVERY POWERCORE-SERIES UNIT

Every unit ships pre-tested, pre-mapped, and certified to UL 2200, EPA Tier 4 Final, and ISO 8528-5.

This matrix lists the standard feature set delivered on every PowerCore-Series shipment. Procurement and engineering teams use this table as the baseline specification against which alternate quotes can be benchmarked. Everything listed is contractual — not optional.

Included as standard on every shipment Available as configured option
Capability Specification Prime
Power-PP
Continuous
Power-CP
Hybrid
PowerCore-H
Controller Architecture WCC-7000 paralleling, DNP3 / Modbus / IEC 61850
Emissions Certification EPA Tier 4 Final · CARB · EU Stage V
Safety Listing UL 2200 · CSA C282 · ISO 8528-5
Enclosure Rating Level 2 sound · IP54 control panel · walk-in available
Remote Telemetry Cellular + satellite gateway, 1-minute cadence
Factory Acceptance Test Witnessed live via encrypted video (units ≥ 1 MW)
Load-Bank Test Package Resistive + reactive, 0.8 PF, 4 hr duration
Black-Start Capability Self-start without grid reference, < 30 sec
Paralleling Switchgear On-board, utility-grade, 32-unit ganging
BESS Integration LFP / NMC containers, DC-coupled architecture
Proprietary Hybrid Controller Diesel dispatch optimizer · 14 active USPTO patents
Uptime Guarantee Contractual 99.97% · 7-year term · per-hour penalties
Field Service Dispatch 24/7/365 · 4 hr 12 min avg. response · 96.4% first-time-fix
Financing Available WesCorp Capital · up to 84-month term · $410M underwritten
Third-party verified by CSA Group audits every 90 days. Updated Rev. 11.2 / Q1 2026.
TIER 03 · CONTROLLER ARCHITECTURE

The PowerCore-Hybrid controller: diesel dispatch logic refined across 1,200+ deployed microgrids.

Hybrid is not a genset with a battery bolted on. The PowerCore-Hybrid controller is a proprietary dispatch optimizer — patented, in production since 2018, and continuously improved against field telemetry from every unit shipped. It sequences diesel run-time against battery state-of-charge, load forecast, fuel cost, and emissions targets in 1-second intervals.

How it operates

  1. 01
    Load Forecasting

    Predicts the 30-minute load curve from 14-day rolling telemetry, ramp-rate constraints, and the operator's published dispatch schedule.

  2. 02
    Battery Dispatch

    Pre-charges the BESS asset during low-load windows; absorbs peak transients with the battery; runs the diesel at its most efficient BSFC point.

  3. 03
    Fuel Optimization

    Selects which gensets run, in what order, and at what load percentage to minimize fuel burned per kWh delivered — averaging 38% less than diesel-only across the deployed fleet.

  4. 04
    Watch-Test Reporting

    Logs every dispatch decision; pushes a daily performance report to the operator; flags deviations from contract before they trigger an alarm.

Why hybrid beats parallel diesel

Two 2 MW diesel gensets running in parallel can hold a 3 MW peak — but they burn fuel continuously, even at 30% load, and they rack up run-hours on the engines that shorten overhaul intervals. A single 2 MW diesel + 1.5 MW BESS holds the same peak, runs the engine at its sweet spot, and burns up to 38% less fuel per kWh delivered. The math is the same on a refinery island, a data hall, a copper mine, or a remote village.

NEXT STEP · 30-MINUTE SCOPING CALL

Specify a system in 30 minutes. Bring your load profile, we'll bring the engineering.

A WesCorp applications engineer — all 84 hold active PE licenses in U.S. jurisdictions — will size the system against your load profile, fuel logistics, emissions jurisdiction, and interconnect requirements. You leave the call with a preliminary one-line diagram, a budgetary kW figure, and an honest read on whether a PowerCore-Series unit is right for your site.

  • Proposal in 10 business days — including witnessed FAT scheduling.
  • Fixed-price contract — no allowances, no open POs on the engine or alternator.
  • Financing term sheet on request — WesCorp Capital, up to 84 months.

Or write directly: [email protected] · Houston HQ, Pasadena TX assembly, 9 regional service depots · 4 hr 12 min emergency dispatch, 24/7/365